Send Message

Professional High Voltage Test Equipment Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsCT PT Testing Equipment

Variable Frequency PT CT Testing Equipment , Portable CT PT Analyzer

Variable Frequency PT CT Testing Equipment , Portable CT PT Analyzer

Variable Frequency PT CT Testing Equipment , Portable CT PT Analyzer
Variable Frequency PT CT Testing Equipment , Portable CT PT Analyzer

Large Image :  Variable Frequency PT CT Testing Equipment , Portable CT PT Analyzer Get Best Price

Product Details:
Place of Origin: Wuhan ,China
Brand Name: Fanke High-voltage
Certification: ISO9001
Model Number: FK-401
Payment & Shipping Terms:
Minimum Order Quantity: One Set
Price: Negotiable
Packaging Details: Export standard wooden case with fumigation free
Delivery Time: 15-20working days
Payment Terms: T/T
Supply Ability: 20 sets / month
Detailed Product Description
Usage: CT PT Volt-ampere Characteristics Tester ,Demagnetization Test Items: CT/PT Volt-ampere ,CT/PT Ratio, DC Resistance,
Other Items: Secondary Load Test Functions, Angular Phase Difference, Secondary Withstand Voltage Advantage: Variable Frequency Method, Portable Type, Full Functions
Test Standard: IEC60044-1, IEC60044-6 Accuracy: < 0.2%
Highlight:

ct pt analyzer

,

ct pt test set

Portable CT/PT Analyzer , CT/PT Excitation Characteristics Tester ,Variable Frequency Testing

 

I. Product Description

 

FK-401 CT/PT Analyzer is a kind of professional testing equipment for CT/PT electric equipments. It can meet all kinds of CT (e.g.: protection, measuring, TP) excitation characteristics ( i.e. voltage characteristics ), ratio, polarity , secondary winding resistance, secondary load, ratio error and phase angle error and other testing requirements , and is also compliant with various types of PT electromagnetic unit excitation characteristics, ratio, polarity , secondary winding resistance , ratio error and phase angle error and other testing requirements.


 

II. Main Performed Test items:

  • All kinds of CT (e.g.: protection, measuring, TP) excitation characteristics ( i.e. voltage characteristics ), ratio, polarity , secondary winding resistance, secondary load, ratio error and phase angle error and other testing requirements ,
  • Compliant with various types of PT electromagnetic unit excitation characteristics, ratio, polarity , secondary winding resistance , ratio error and phase angle error and other testing requirements.
  • Automatically gives the knee voltage / current, 10% ( 5% ) error curve , accuracy limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr), saturated and unsaturatied inductors and others CT, PT parameters.
  • Meet IEC60044-1, IEC60044-6 CT/PT standard.

 

 

III. Technical features

 

1. Full-featured , meet all kinds of CT (e.g.: protection, measuring, TP) excitation characteristics ( i.e. voltage characteristics ), ratio, polarity , secondary winding resistance, secondary load, ratio error and phase angle error and other testing requirements , also compliant with various types of PT electromagnetic unit excitation characteristics, ratio, polarity , secondary winding resistance , ratio error and phase angle error and other testing requirements.

2. Automatically gives the knee voltage / current, 10% ( 5% ) error curve , accuracy limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr), saturated and unsaturatied inductors and others CT, PT parameters.

3. Meet IEC60044-1, IEC60044-6 CT/PT standard.

4. Based on an advanced low-frequency testing theory, able to test knee point of the CT test up to 30KV.

5.Device can store 2000 groups of test data, non-volatile. After the test is completed with U disk to the PC data analysis software, and generate reports in WORD file.

6. Testing is simple and convenient, one button operation completes CT resistance, excitation, ratio and polarity tests,.Except for load test , various other CT tests are using the same wiring.

7. Easy to carry, instrument weight<9kg

 

 

IV. Test  Data

 

Testing purposes Protective CT
Output 0~180Vrms, 12Arms,36A(peak value)
Voltage measurement accuracy ±0.2%
CT ratio measurement Range: 1~30000
Accuracy: ±0.2%
PT ratio measurement Range: 1~10000
Accuracy: ±0.2%
Phase measurement Resolution: 0.5min
Accuracy: ±5min
Secondary winding resistance measurement Range: 0~300Ω
Accuracy: 2%±2mΩ
AC load measurement Range: 0~300VA
Accuracy: 2%±0.2VA
Input supply voltage AC220V±10%, 50Hz
Work Environment Temperature:-10℃ ~ 50℃, humidity≤90%
Dimension & weight Dimension: 340×300×150mm3, weight≤9kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 