Product Details:
Payment & Shipping Terms:
|
Usage: | CT PT Volt-ampere Characteristics Tester ,Demagnetization | Test Items: | CT/PT Volt-ampere ,CT/PT Ratio, DC Resistance, |
---|---|---|---|
Other Items: | Secondary Load Test Functions, Angular Phase Difference, Secondary Withstand Voltage | Test Output: | 0-2500V Adjustable; 0-15A/0-600A/0-1000A |
DC Resistance: | Test Range : 0.1-20Ω | Secondary Load: | Test Output :0-200A |
Secondary Withstand Voltage: | Test Output: 0-2500V | Accuracy: | < 0.5% |
High Light: | ct pt analyzer,secondary current injection test set |
Mutual Inductor Multi-function Tester , CT/PT Excitation Characteristics Tester
I. Product Description
FKFA-II Mutual Inductor Multi-function Tester is applied for measuring CT/PT volt-ampere characteristic, 5%, 10% and 15% error curve, ratio, polarity, angle error, ratio error, secondary DC resistance and secondary load, secondary loop, secondary withstand voltage and function of demagnetization. It has 600A and 2500V output.
II. Main Performed Test items:
III. Technical features
1. Full-function, can test CT/PT -ampere characteristic, 5%, 10% and 15% error curve, ratio, polarity, voltAngle error, ratio error, secondary DC resistance and secondary load, secondary loop, secondary withstand voltage and function of demagnetization.
2. 600A max. current output , max. test voltage up to 2500V.
3. With a large storage capacity, 2000 sets of test data can be stored and the data will never be lost.
4. Automatic calculating knee point, with test data printing function.
5. The output of the device is all real voltage and current under the standard sine wave at 50Hz, which can effectively simulate the actual state of the tested transformer.
IV. Test data
Input voltage |
Maximum output voltage |
Maximum output current |
Power |
measurement accuracy |
|||
CT volt-ampere output |
220V | 0—2500V | 15A | 3KVA | < 0.5% | ||
CT ratio output |
220V | 0-8V | 0—600A/1000AOptional | none | < 0.5% | ||
CT ratio measurement |
The maximum ratio display: 999.9K: 5 / 1 |
< 0.5% | |||||
PT ratio measurement |
The maximum ratio display:999.9K:100,150,100/3,100/ |
< 0.5% | |||||
DC resistance measurement |
The maximum resistance measurement: 0.1-20Ω |
Less than 1Ω:3% More than 1Ω: <1% |
|||||
angular phase difference |
Minimum display: 0.01’ Accuracy::±10’ |
Ratio Difference |
Minimum display: 0.01% Accuracy:<0.5% |
||||
The secondary load test |
Output Current: 0-200A Time:1~5mins |
The secondary withstand voltage |
output Voltage: 0-2500V Time:1~5mins |
||||
Working temperature |
-10~55℃ |
Working voltage |
AC220V(±20%)50HZ | ||||
Host volume |
420×300×270 |
Host weight |
26Kg |
Contact Person: Sales Manager
Tel: +8613707144739