Product Details:
Place of Origin: Wuhan , China
Brand Name: Fanke High-voltage
Certification: ISO9001
Model Number: ML360
Payment & Shipping Terms:
Minimum Order Quantity: One unit
Price: Negotiable
Packaging Details: Export standard wooden case with fumigation free
Delivery Time: 5-10work days
Payment Terms: T/T
Supply Ability: 20units/1months
Detailed Product Description
Usage: Multifunctional Phase Parameter &Vector Comprehensive Tester Appliaction: Secondary Circuit Test Tools
Test Parameter: U1、I1、φ1、U2、I2、φ2、U3、I3、φ3、φU1U2、φU2U3、φU3U1、φI1I2、φI2I3、φI3I1 And U1F Phase Angle: 0 ~ 360.0 ° For U-U, U-I, I-I
Test Resolution: Phase: 0.1 ° / Frequency :0.01Hz /Voltage:10mV /Current: 0.1mA Test Range: Phase: 0 ~ 360.0 ° / Frequency 45-65Hz /Voltage:10-500V /Current: 10mA-120A
Save: RS232 Communication Port Continuous Working Time: 15 Hours , Rechargeable Battery In It
High Light:

relay test kit

,

protection relay test equipment

Portable Vector Analyzer , Multifunctional Phase Parameter Comprehensive Tester,Secondary Circuit Test Tools

 

 

I. Product Description and Advantages:

  • Large screen dot matrix LCD display, can measure simultaneously, with the screen display of 16 parameters, such as U1,I1,φ1,U2,I2,φ2,U3,I3,φ3,φU1U2,φU2U3,φU3U1,φI1I2,φI2I3,φI3I1 and U1F.
  • Voltage measurement resolution of 10 mV, current measurements up to the highest resolution 0.1 mA.
  • In the measurement range of 45.00 ~ 65.00 Hz voltage frequency, resolution of 0.01 Hz.
  • In the range of 0.0 ~ 360.0 °, measure the phase between U-U, U-I, I-I, the resolution of 0.1 °. While testing phase, require input voltage range of 10 ~ 500V, input current range of 10 mA ~ 120A. Void phase measurements with the symbol "..." indication to avoid that the operator will normally take the phase value "0.0 °" as a valid measurement when no signal is input.
  • Direct dynamic or static vector graphics display system.
  • After choosing ML250 clamp type current transformer, detect the polarity of the transformer, and direct display the ratio R (R = I1/I2) between I1 and I2 and the phase φI1I2 reflecting polarity between I1 and I2.
  • Built-in memory save 50 group (panel) measurements data. By operating buttons on the panel access to the saved historical data sets and vectors.
  • With RS-232 interface, instrument measurement data can be uploaded to a PC and formed a database for storage by PC management software, or print the report for file.
  • Install rechargeable battery in it, the continuous working time is up to 15 hours or more when the LCD backlight is off, and for 11 hours or more when the LCD backlight is on.
  • Using software calibration techniques, simple operation, reliable data, long-term stability.

 

 

II. Main technical parameters and Model comparision:

 

1,Voltage channels,floating input

Voltage limit 400V Measuring rate once / s
Input method Floating input Max. input 500V
Measuring range 10.00V~500.00V Impedance input 200KΩ
Display 5 d Response mode True RMS response
Measuring rate once / s

 

2,Current channels,clamp type current transformer

Input method clamp type CT input Response mode True RMS response
Display 4.5d Measuring rate once / s

 

3,Voltage withstand: AC voltage withstands under 2K / 50 Hz sine wave for 1 min.

4,Insulation resistance: Insulation resistance between test points is greater than 10 MΩ.

5,charge power :160V~250V, 50 Hz.

6,Charging period when power off: The maximum charging period is three hours when it is power off.

7,Discharging time when power on: the continuous working time is for 15 hours or more when the LCD backlight is off, and for 11 hours or more when the LCD backlight is on.

8,Charge-discharge cycle counts: 500 times

9,Natural discharge: At 20℃, after one month, the full battery will be 70% of the initial capacity.

10,Dimension: 248*188*72 weight : 1.5 Kg

 

 

III. Test accessories

 

1,Testing wire for voltage: 1 set(6pcs)

2,ML10 Clamp type CT        3pcs   

3,Two-core charging power line:1 set

4,RS232 communication line: 1 piece

5,Software CD: 1 copy

6,Braces for the instrument: 1 piece

7,Portable suitcase: 1 piece

8,Instruction manual : 1 copy

9,Certificate of quality: 1 copy

10,Packing list: 1 copy

11,Fuse :φ5×20 / 1A 3 pieces

12,Power input jack: 3 pieces