Test Principle: | Impulse Current Method For PD Detecting | Usage: | Partial Discharge Test |
---|---|---|---|
Refer Standard: | IEC60270 Partial Discharge Measurement ;DL/T 417 Guideline For Local Measurement Of Partial Discharge Of Electric Equipment ; | Application: | Power Transformer ,CB, Bushing, CT,PT ,discloser And So On |
PD Display: | Ellipse, Expand, Beeline | Capacitance Range: | 6pF~250uF Can Be Detected |
High Light: | pd testing equipment,partial discharge test set |
Partial Discharge Detecting Tester , PD Detecting Instrument , Impulse Current Method PD Tester
1.Product introduction:
Due to manufacturing or installation defects, discharge occurs in the insulated portion of the live cable end (joint) until insulation breakdown damage occurs, and even a fire or explosion at uncertain defects may occur. Therefore, how to find the hidden troubles before the accident is the key to solve the problem, which makes the discharge detection necessary for power equipments.
The model JF2002 is a kind of impulse current method partial discharge inspection instrument It has the feature of small volume, excellent performance and easy operation.
II.Main Components:
SN | Name of equipment | Type and specification | Unit | Qty |
1 | Host machine | JF-2002 | Piece | 1 |
2 | JZF Series calibrator | JZF-10 | Piece | 1 |
3 | Amplifier | piece | 1 | |
4 | Input signal unit | SN 2, 3,4 | set | 1 |
5 | Standard connection wire | Set | 1 |
III. Detecting principle figure
Note : The PD free test transformer set (power frequency voltage withstand test set) rises the target testing voltage to tested object (such as power transformer ,CB, bushing, CT,PT ,discloser and so on )which PD detecting needed , the coupling terminals of voltage divider will has some PD coupling signal to the PD detecting tester JF 2002, then get the PD level from the tested object.
VI. Technical Parameters of PD tester JF2002
1.Keywords: time base frequency ,Display, Change with measurement fuctions
2.Integrated design, covering 10kHz~300kHz, Meet IEC60270 standard.
3.Capacitance range of measured object: 6pF~250uF
Measuring sensitivity and Max. Current as the table
Input unit SN.optional | Measured object Cx range | Sensitivity(PC) | Permitted circuit current | |
Imbalance circuit | Balance circuit | |||
1 | 0~25~100pF | 0.02 | 30mA | 0.25A |
2 | 25~100~400pF | 0.04 | 50mA | 0.5A |
3 | 100~400~1500pF | 0.06 | 120mA | 1A |
4 | 400~1500~6000pF | 0.1 | 0.25A | 2A |
5 | 1500~6000~25000pF | 0.2 | 0.5A | 4A |
6 | 0.006~0.025~0.1μF | 0.3 | 1A | 8A |
7 | 0.025~0.1~0.4μF | 0.5 | 2A | 15A |
8 | 0.1~0.4~1.5μF | 1 | 4A | 30A |
9 | 0.4~1.5~6.0μF | 1.5 | 8A | 60A |
10 | 1.5~6.0~25μF | 2.5 | 15A | 120A |
11 | 6.0~25~60μF | 5 | 25A | 200A |
12 | 25~60~250μF | 10 | 50A | 300A |
7R | pure resistance | 0.5 | 2A | 15A |
4.Time base of ellipse scan:
5.Displaying Unit:
A reactangle oscillograph tube(124×104mm2), which has brightness and focus knobs
6.Amplifier :
7.Time window
8.Pulse peak meter
9.Measuring voltmeter
10.Zero mark system
11. Dimension : 530×550×220mm weight :22kg