Product Details:
Payment & Shipping Terms:
|
Test Principle: | Variable Frequency Resonant Circuit | Test Item: | AC Withstand Voltage Test Under 108KV |
---|---|---|---|
Max.capacity: | 108KVA | Max. Voltage: | 27KV , 54KV, 81KV , 108KV |
Design Feature: | Portable Type , Lighter Single Piece Weight, Special For On-site Installation And Test | Component:: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz | Duty Cycle: | 60 Mints |
Test Accuracy: | No Less Than 1.5% | Output Waveform: | Good Sine Wave |
Test Object: | 35KV Cable , 10KV Cable, 35KV Power Substation | Test Standard: | IEC 60060-1:2010;IEC 62271-203:2011 For GIS, IEC 60840:2011 For XLPE Cable; |
High Light: | high voltage vlf hipot instruments,vlf cable testing equipment |
Portable Variable Resonant Withstand Voltage Test Set , For 35KV &10KV Cable Test , 30~300Hz Test Frequency
I. Product Usage :
This test set model FKTF-81KVA/27KV, 54KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, busbar in 35KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 27KV ,54KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test
Test range of the set is as following:transformer
1. 500m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 60min.
2, 2000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.
3, 10kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 54kV, test time 1min.
4, CB,CT/PT, busbar in 35KV power substation , test frequency 40-300Hz, test voltage does not exceed 95kV, test time 1min.
The whole test set consists of variable frequency power source , excitation transformer , 3pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV power sub-station
II. General Technical Data
Application:
Cross-linked cables with voltage of 10KV,35KV;
Features:
The test is with variable frequency resonance way, and the reactor is with cordwood structure.
Test frequency:30~300HZ or 35~75HZ;
Output voltage waveform is sine waveform,Waveform deviation factor≤1%;
Easy connection and operation;
Small size and light weight of each component is easy for carry and field test;
It has an intelligent variable frequency power supply, with high automaticity and protective function.
Cross-linked Cable Voltage Withstand Test System :Length of cable:1~10km (can be ordered);
Weight of single piece:25kg~50kg;
III. Main Components:
SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension |
1 | Variable frequency power | OEM | 1piece | 35kgs | OEM |
2 | Excitation transformer | OEM | 1piece | 35kgs | OEM |
3 | HV resonant test reactor | OEM | 3pieces | 42kgs | OEM |
4 | Capacitive divider | OEM | 1set | 10kgs | OEM |
5 | Special test accessories | 1set |
IV. Test priciple :
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
V. Other Optional Model
1. For GIS on-site test
Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
CHX-135KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-270KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-216KVA/216KV | 27KV*8 | 1A | 216KVA | For 123KV and below GIS |
CHX-270KVA/270KV | 27KV*10 | 1A | 270KVA | For 145KV and below GIS |
CHX-275KVA/275KV | 275KV | 2A | 275KVA | For 170KV and below GIS |
Special requirement can be made by order |
2. For 45KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-108/54 | 54KV | 2A | 108KVA | 45kV cable≤1km |
CHX-216/54 | 54KV | 4A | 216KVA | 45kV cable≤2km |
CHX-324/54 | 54KV | 6A | 324KVA | 45kV cable≤3km |
CHX-432/54 | 54KV | 8A | 432KVA | 45kV cable≤4km |
CHX-540/54 | 54KV | 10A | 540KVA | 45kV cable≤5km |
CHX-1080/54 | 54KV | 20A | 1080KVA | 45kV cable≤10km |
Special requirement can be made by order |
3. For 66KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-160/80 | 80KV | 2A | 160KVA | 66kV cable≤0.5km |
CHX-320/80 | 80KV | 4A | 320KVA | 66kV cable≤1km |
CHX-640/80 | 80KV | 8A | 640KVA | 66kV cable≤2km |
CHX-960/80 | 80KV | 12A | 960KVA | 66kV cable≤3km |
CHX-1280/80 | 80KV | 16A | 1280KVA | 66kV cable≤4km |
CHX-1600/80 | 80KV | 20A | 1600KVA | 66kV cable≤5km |
CHX-3200/80 | 80KV | 40A | 3200KVA | 66kV cable≤10km |
CHX-9600/80 | 80KV | 120A | 9600KVA | 66kV cable≤20km |
Special requirement can be made by order |
VI. On-site insulation test standard table from IEC 60840:2011 for XLPE cable
Contact Person: Sales Manager
Tel: +8613707144739