Professional High Voltage Test Equipment Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPower Transformer Testing Equipment

Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance

Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance

Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance
Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance

Large Image :  Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance Get Best Price

Product Details:
Place of Origin: China
Brand Name: Fanke High-Voltage
Certification: ISO9001
Model Number: FKGST
Payment & Shipping Terms:
Minimum Order Quantity: One unit
Price: Negotiable
Packaging Details: Export standard wooden case with fumigation free
Delivery Time: 10 work days
Payment Terms: T/T
Supply Ability: 10units/month
Detailed Product Description
Usage: Capacitance & Tan Delta Tester Within 10KV Or 12KV HV Output: 0~10KV(0-12KV Can Be Ordered)
Test Object: Power Transformer , Motor , Bushing And So On. CVT Self-excitation Low Pressure Output: Output Voltage 3~50V, Output Current 3~30A
Output Current: Internal HV Output , 10μA~1A Anti-interference: Variable Frequency Method, 5mA
High Light:

distribution transformer testing equipment

,

transformer test system

Transformer Capacitance & Tan Delta Tester , Automatic Tan Delta Tester , Dielectric Loss & Capacitance​

 

I. Products Description 

 

Model FKGST Automatic 10KV Capacitance &Dissipation Factor Test Set is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The meter is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It’s also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it’s running automatically and then outputs the results on LCD display and prints the results automatically.

 

FKGST Tan Delta (dissipation factor) Tester consists of variable frequency power, tan delta bridge, testing transformer and standard capacitor inside the tester. Variable frequency power can produce five kinds of frequency: 45Hz, 50Hz, 55Hz, 60Hz and 65Hz under which test can be done. Variable frequency technique adopted in this tester can ensure high accuracy in high interference environment.

 

II. Test principle 

Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance 0

                                                             Fig 1 Wiring Diagram of Main Power

RX1---Sampling resistance in ungrounded test specimen measurement

RX2---Sampling resistance in grounded test specimen measurement

CN---Standard capacitor

RN---Sampling resistance of reference signal

CVT---Voltage output terminal in CVT measurement by means of self-excitation.

 

III. Technical Parameters

  1. Capacitance range: Internal HV: 3pF-60000pF/10kV;  60pF-1μF/0.5kV
  2. Test accuracy: Cx: ±(reading×1%+1pF)

         tgδ: ±(reading×1%+0.00040)

  3. External HV: 3pF-1.5μF/10kV;  60pF-30μF/0
  4. Resolution: Maximum 0.001pF, 4 valid figures.
  5. tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles.
  6. Test current range: 10μA-1A
  7. Internal HV: Set voltage range: 0.5-10kV
  8. Maximum output current: 200mA
  9. Buck-bust method: continuous stepless regulation
  10. Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
  11. External HV: In case of UST, maximum test current is 1A, and power frequency or variable frequency is 40-70Hz
  12. In case of GST, maximum test current is 10kV/1A, and power frequency or variable frequency is 40-70Hz
  13. CVT self-exciting low voltage output: Output voltage 3-50V, output current 3-30A
  14. Measuring duration: About 40s, depending on measuring method
  15. Input power supply: 180V-270VAC, 50Hz/60Hz±1%, supplied by alternating current or generator
  16. Computer interface: Standard RS232 interface
  17. Printer: WH-A7 mini-type thermal printer
  18. Environment temperature: -10-50
  19. Relative humidity: <90%
  20. Overall dimension:460×360×350mm
  21. Weight:28kg


III. Configuration:

 

SN NAME Qty
1 FKGST Automatic 10KV Capacitance &Dissipation Factor Tester 1set
2 10 meters Hipot measuring signal lines (red) 1pec
3 10 meters measuring signal lines (black) 2pecs
4 8 m CVT Low voltage output line 1pec
5 Power line 1pec
6 8 m Earth line 1pec
7 Spare printing paper 1pec
8 5A fuse 1pec
9 Feltpad 1pec
10 Manual 1pec
11 certificate of inspection 1pec
12 accessory case fro connection lines 1pec
 

 

Contact Details
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

Contact Person: Sales Manager

Tel: +8613707144739

Send your inquiry directly to us