Product Details:
Payment & Shipping Terms:
|
Used Field: | Electrical Test Apparatus | Application: | AC And DC Hipot Test |
---|---|---|---|
Test Output: | AC 20KV , DC 20KV | Advantage: | Programmable |
Current Range: | 200uA、2mA、10mA | Leakage Current Range: | 10mA |
Test Accuracy: | ±(2% Reading +5V) | Test Timer: | 0.0-999.9s |
High Light: | ac hipot tester,high voltage hipot tester |
Portable Type AC Hipot Tester , DC Hipot Tester , 20KV Safety Tester , Programmable
I. Product Description
The 9920A/9920B Hipot tester is an ultra-high voltage and programmable safety tester with an output voltage of 20kV. It can be widely used in the safety tests of household appliances, transformer, electrical equipments and components.
II. Refer Standard
III. Technical Data and optional model:
MODEL | 9920A | 9920B | |||
AC | Output | range | 1.00kV~20.00kV | --------- | |
accuracy | ±(2% reading +5V) | --------- | |||
resolution | 10V | --------- | |||
Max.output capacity | 200VA | --------- | |||
Max.rated current | 10mA | --------- | |||
Lower limit current range | 0~20mA, | --------- | |||
Current gear | 200uA,2mA,10mA | --------- | |||
Output waveform | sine wave | --------- | |||
Output waveform distortion | ≤ 2% (no load or pure resistive load) | --------- | |||
Crest factor | 1.3~1.5 | --------- | |||
Output signal type | DDS+ amplifier | --------- | |||
Voltage rise time | 0.3s ~ 999.9s | --------- | |||
Test time | 0.3s ~ 999.9s | --------- | |||
Voltage drop time | 0.3s ~ 999.9s | --------- | |||
Interval time | 0.0s~999.9s | --------- | |||
Output voltage mode | N mode, G mode | --------- | |||
DC | Output | range | --------- | 1.00kV~20.00kV | |
accuracy | --------- | ±(2% reading +5V) | |||
resolution | --------- | 1V | |||
Max.output capacity | --------- | 200W | |||
Max.rated current | --------- | 10mA | |||
Current gear | -------- | 2uA,20uA,200uA,2mA,10mA | |||
Ripple coefficient | --------- | ≤5% | |||
Maximum charging current | --------- | 10mA | |||
Voltage rise time | --------- | 0.3s ~ 999.9s | |||
Test time | --------- | 0.3s~999.9s | |||
Voltage drop time | --------- | 0.3s ~ 999.9s | |||
Interval time | --------- | 0.3s~999.9s | |||
Delay alarm time | --------- | 0.3s~999.9s | |||
Output voltage mode | N mode, G mode | ||||
Voltage meter | range | 1.00kV~20.00kV | |||
accuracy | ±(2%reading+5V) | ||||
resolution | 10V | ||||
Display value | RMS value | ||||
Current meter | Test range | AC | 0 ~ 10mA | ||
DC | -------- | 0 ~ 10mA | |||
resolution | AC | 200uA gear:0.1uA, 2mA gear:1uA, 10mA gear:10uA | |||
DC | -------- | 2uA gear: 0.001uA, | |||
Test accuracy | ≥2mA is ±(2%+5 words), <2mA is ±(3%+5 words) | ||||
Error Offset function | The current of the test leads and accessories can be subtracted. | ||||
Test mode | GND mode: RETURN terminated chassis | ||||
Timer | range | 0~999.9s | |||
resolution | 0.1s | ||||
accuracy | ±(0.1%+50ms) |
VI.Supply list
Contact Person: Sales Manager
Tel: +8613707144739