Professional High Voltage Test Equipment Manufacturer

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsAC Resonant Test System

High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test

High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test

High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test
High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test

Large Image :  High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test Get Best Price

Product Details:
Place of Origin: China
Brand Name: Fanke High-voltage
Certification: ISO9001
Model Number: CHX-108KVA/27KV,108KV
Payment & Shipping Terms:
Minimum Order Quantity: One unit
Price: Negotiable
Packaging Details: Export Standard Wooden Case With Fumigation Free
Delivery Time: 25-30 Work Days
Payment Terms: T/T
Supply Ability: 10units/1months
Detailed Product Description
Test Principle: Variable Frequency Resonant Circuit Test Item: AC Withstand Voltage Test Under 108KV
Max.capacity: 108KVA Max. Voltage: 27KV , 54KV, 81KV , 108KV
Design Feature: Portable Type , Lighter Single Piece Weight, Special For On-site Installation And Test Component:: V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test Frequency: 30-300Hz Duty Cycle: 60 Mints
Test Accuracy: No Less Than 1.5% Output Waveform: Good Sine Wave
Test Object: 35KV Cable , 10KV Cable, 35KV Power Substation Test Standard: IEC 60060-1:2010;IEC 62271-203:2011 For GIS, IEC 60840:2011 For XLPE Cable;
High Light:

high voltage resonant test system

,

high voltage testing of electrical equipments

Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and Power Substation Test

 

I. Product Usage :


This test set model CHX-108KVA/27KV, 108KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, busbar in 35KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 27KV ,54KV,108KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive  test or hand-over test on  AC withstand voltage test 

 

Test range of the set is as following:transformer

1. 500m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 60min.

2, 2000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.

3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.

4, CB,CT/PT, busbar in 35KV power substation , test frequency 40-300Hz, test voltage does not exceed 95kV, test time 1min.

 

The whole test set consists of variable frequency power source , excitation transformer , 4pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV power sub-station

   

 

II. General Technical Data

  1. Rated capacity: 108kVA;
  2. Input power: three-phase 380V voltage, frequency is 50Hz;
  3. Rated voltage: 27kV, 54kV,81KV, 108KV
  4. Rated current: 1A; 4A;
  5. Working frequency: 30-300Hz;
  6. Device output waveform: sine wave
  7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
  8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
  9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
  10. Quality factor: device itself Q≥30 (f=45Hz);
  11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
  12. Measurement accuracy: system effective value 1.5;


III. Main Components:

 

SN Name of Components Type and specification Qty. Each weight Each Dimension
1 Variable frequency power FKVF-5kW/380V 1piece 35kgs 450*450*500mm
2 Excitation transformer CQSB(J)-5kVA/1.25KV,5KV 1piece 35kgs 450*350*450mm
3 HV resonant test reactor CHX(kf)-27kVA/27kV 4pieces 42kgs D350*H400mm
4 Capacitive divider TRF-110kV/1000pF 1set 10kgs D150*H850mm
5 Special test accessories   1set    

 

 
 
 
 
 
 
 
 
 
 

IV. Test priciple :
High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test 0
 
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
 
 
V. Main Measuring and control software panel:  
High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test 1
 Note: This is the software panel before start test for parameter setting
 

 

 
VI.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .

 
VII. Other Optional Model 

 

1. For  GIS on-site  test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-135KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-270KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-216KVA/216KV 27KV*8 1A 216KVA For 123KV and below GIS
CHX-270KVA/270KV 27KV*10 1A 270KVA For 145KV and below GIS
CHX-275KVA/275KV 275KV 2A 275KVA For 170KV and below GIS
Special requirement can be made by order

 

 

2. For 45KV  XLPE cable on-site test 

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-108/54 54KV 2A 108KVA 45kV cable≤1km
CHX-216/54 54KV 4A 216KVA 45kV cable≤2km
CHX-324/54 54KV 6A 324KVA 45kV cable≤3km
CHX-432/54 54KV 8A 432KVA 45kV cable≤4km
CHX-540/54 54KV 10A 540KVA 45kV cable≤5km
CHX-1080/54 54KV 20A 1080KVA 45kV cable≤10km
Special requirement can be made by order

 

3. For 66KV XLPE cable on-site test

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-160/80 80KV 2A 160KVA 66kV cable≤0.5km
CHX-320/80 80KV 4A 320KVA 66kV cable≤1km
CHX-640/80 80KV 8A 640KVA 66kV cable≤2km
CHX-960/80 80KV 12A 960KVA 66kV cable≤3km
CHX-1280/80 80KV 16A 1280KVA 66kV cable≤4km
CHX-1600/80 80KV 20A 1600KVA 66kV cable≤5km
CHX-3200/80 80KV 40A 3200KVA 66kV cable≤10km
CHX-9600/80 80KV 120A 9600KVA 66kV cable≤20km
Special requirement can be made by order

 

 

 

VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test 2

Contact Details
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

Contact Person: Sales Manager

Tel: +8613707144739

Send your inquiry directly to us