Product Details:
Payment & Shipping Terms:
|
Used Field: | Electrical Test Equipment | Application: | DC Hipot Test And Leakage Current Test |
---|---|---|---|
Test Range: | 80KV And 5mA | Voltage Display: | 1.0% Of Reading ± 0.2KV |
Current Display: | 1.0% Of Reading ± 2 | Ripple: | ≤0.5% |
Checking To: | Electric Arresters , Insulators , Power Cable | Working Time: | Continuous Use 30mints |
High Light: | hipot test kit,hipot test set |
Portable DC Hipot Test Set , High Voltage Measurement Equipment , Hipot Test Equipment
I. Product Description
The test set is mainly composed of control box, cylinder type HV booster , fully shielded microammeter and DC discharge rod. The control box is used for control the test process and display test data , the cylinder type HV booster is to output DC high voltage , the fully shielded microammeter is for accurate display of leakage current and transfer the data to the control box.
Newly researched, designed, and manufactured according to Common technical condition for portable DC HV generator of China Industry Standard, the ZGF series DC hipot test set is a technology product of new era, suitable for DC high voltage test and leakage current measurement on zin oxide arrester ,magnetic blow-out arrester, power cable, power motor or generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant and so on.
Major parts of ZGF series high frequency DC high voltage generator adopt components made in America, Germany, Japan and so on with advanced technology, making equipment more reliable, more stable. Multi-voltage tube is developed and produced with German technology. With the features of small size, large capacity, strong overload capacity, and easy field operation test, high frequency transformer specially is designed by experts. Looking ahead, the company will continue to actively develop the market, take quality and credibility as its life, constantly improve its technology, develop a sophisticated quality products to meet the needs of users, and strive to open up and recast a new century glory.
II. Product features
III. Test circuit connection figure
Note : The control box(cabinet) is used for control the test process and display test data , the cylinder type HV booster(HV generator) is to output DC high voltage , the fully shielded microammeter(uA) is for accurate display of leakage current and transfer the data to the control box.
the discharge rod is for earthing grounding and discharge after finish DC test.
IV. Product Models and Technical Parameters
specification technic parameter |
40/4 | 60/2 | 60/5 | 120/2 | 120/3 | 120/10 | 200/2 | 220/2.5 | 200/10 | 300/2 | 300/3 |
Rated voltage(KV) | 40 | 60 | 60 | 120 | 120 | 120 | 200 | 220 | 200 | 300 | 300 |
Rated current(mA) | 4 | 2 | 5 | 2 | 3 | 10 | 2 | 2.5 | 10 | 2 | 3 |
Rated power(W) | 160 | 120 | 300 | 240 | 360 | 1200 | 400 | 550 | 2000 | 600 | 900 |
Voltage meter precision | number on voltage meter ±(1.0 %reading±0.2KV) | ||||||||||
Current meter precision | number on current meter ±(1.0 %reading±0.2mA) | ||||||||||
Ripple coefficient | ≤0.5% | ||||||||||
Voltage stabilization | stochastic wave ,≤1% when power wave±10% | ||||||||||
Overloading ability | overstep 10% of rated voltage when loading nothing for ten minutes; the biggest charge current can be 1.5 times of rated current | ||||||||||
power | single-phase alternating current power of 50HZ 220V±10% | ||||||||||
working | incontinuous use | ||||||||||
The time should be no more than 30 minutes when continuously use it | |||||||||||
Work condition | temperature:-10~40℃ | ||||||||||
relative humidity:≤85% when room temperature is 25℃ | |||||||||||
height above sea level:below1500 meters | |||||||||||
capacitance | capacitance of the tested res is absoluteness | ||||||||||
Can be charged with 1.5 times of rated current | |||||||||||
configuration | electric insulated Voltage Multiplier is made of epoxy FRP(Fiberglass-Reinforced Plastics) | ||||||||||
Air insulated,without leak | |||||||||||
characteristic of Control box | One button for high precision of 0.75UDC--1mA(precision≤1.0%)is suit to do zinc oxide lightning arrester test | ||||||||||
overvoltage protection use dialing code set,be clear at a glance | |||||||||||
International standard box withTwo kind of using way(can be take out from the box for using) makes it easy to use. |
V. Supply range of one test set
Contact Person: Sales Manager
Tel: +8613707144739