Product Details:
Payment & Shipping Terms:
|
Application: | On Site Power Transformer Oil Purifier | Filtering Method: | Double Stages Vacuum Method |
---|---|---|---|
Material: | Carbon Steel | Water Content: | <=5ppm |
Raw Material: | Dielectric Oil, Transformer Oil, Insulation Oil | Gas Content: | <=0.1~0.3% |
Power(W): | Made By Order | Special For: | 66kV~500KV Power Transformer Oil Filtering |
Highlight: | transformer oil bdv test kit,insulating oil dielectric strength tester |
Transformer Insulation Oil Purifier , Vacuum Insulation Oil Filter , Double Stages Vacuum
I. Products Description
Dissolved gasses in transformer oil can cause arcing, corona discharges, and overheating--reducing the electrical efficiency and lifetime of the transformer. Likewise, water contamination at levels as low as 30 ppm (parts per million) can adversely affect the insulating strength of the oil. With ever-increasing standards for energy efficiency of power distribution transformers, the need to effectively degas will become even more important in the future. particles contamination will also affect the function of insulating oil. So we need to clean used transformer oil.
Vacuum oil filter is used to filter high voltage transformer oil, suitable for 66KV-500KV Transmission and Distribution equipment handling. It gives oil treatment and vacuum drying to the wet electrical equipment in the field. It also vacuumizes for the newly transformers or maintenance ones and pours vacuum grease into them.
DZL SERIES Double StagesTransformer Oil Purifier is mainly used to improve the properties of insulation oil for 66KV to 500KV project. It can remove trace water, gas, particulate matters etc. from the insulating oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which has insulation system.DZL series Double Stage High Vacuum Transformer Oil Purifying Machine With Trailer specialize in purifying branded oil, insulating oil of high voltage and super high voltage transformer. Additionally, it is suitable for treating low viscosity lubrication oil. Dissolved gasses in transformer oil can cause arcing, corona discharges, and overheating--reducing the electrical efficiency.
II. Advantage
III.Technical parameters and optional model of Transformer Oil Purifier
Index item | Unit | DZL-50 | DZL-100 | DZL-150 | DZL-200 | DZL-250 | DZL-300 | DZL-500 | |||
Flow | L/min | 50 | 100 | 150 | 200 | 250 | 300 | 500 | |||
Vacuum | Mpa | —0.09 ~ —0.099 | |||||||||
Pressure | Mpa | ≤0.4 | |||||||||
Breakdown voltage | Kv | ≥55 | ≥60 | ≥60 | ≥60 | ≥60 | ≥60 | ≥60 | |||
Constant temperature control range | ℃ | 20~80 | |||||||||
Power | ~50 Hz 380V | ||||||||||
Noise | dB(A) | ≤70 | ≤75 | ≤80 | ≤80 | ≤80 | ≤82 | ≤85 | |||
Heating power | Kw | 24 | 60 | 60 | 99 | 90+30 | 120 | 180 | |||
Total electric power | Kw | 29.5 | 66 | 69 | 99 | 130 | 132 | 195 | |||
Pipe diameter | mm | 32 | 38 | 38 | 44 | 64 | 50 | 60 | |||
Weight | Kg | 340 | 450 | 520 | 560 | 650 | 670 | 900 | |||
Dimension | L | mm | 1500 | 1680 | 1700 | 1800 | 1800 | 2000 | 2650 | ||
W | mm | 850 | 1150 | 1000 | 1200 | 1400 | 1250 | 1650 | |||
H | mm | 1500 | 1600 | 1650 | 1750 | 1850 | 2000 | 2300 |
Contact Person: Sales Manager
Tel: +8613707144739