Product Details:
Payment & Shipping Terms:
|
Test Principle: | Variable Frequency Resonant Circuit | Test Item: | AC Withstand Voltage Test Under 52KV , 132KV |
---|---|---|---|
Max.capacity: | 810KVA | Max. Voltage: | 54KV , 135KV |
Test Frequency: | 30-300Hz | Duty Cycle: | 60 Mints |
Test Accuracy: | No Less Than 1.5% | Output Waveform: | Good Sine Wave |
Test Length Of Cable: | 5km Of 35KV Cable , 1km Of 132KV Class | Test Standard: | IEC 60060-1:2010;IEC 62271-203:2011 For GIS, IEC 60840:2011 For XLPE Cable; |
High Light: | 132KV HV Cable Testing Equipment,35KV HV Cable Testing Equipment,300Hz AC Resonant Test System |
35KV /132KV Hv Cable Testing Equipment 30-300Hz ,Resonant Withstand Voltage Test Set
Features
1. This withstand voltage equipment has small volume, light weight and portable test system.
2. The power supply adopts 220V single-phase power supply or 380V single power supply, which is convenient for on-site power collection.
3. The reactor adopts dry epoxy pouring, which is beautiful and reliable, suitable for all kinds of cables.
4. Equip with low harmonic patented technology, lower than 5% international standard and protect the main transformer, generator and other equipment from high voltage harmonic damage.
5. Equip with the function of monitoring peak value according to international standard, which can monitor high voltage test waveform in real time.
6. Easy to operation, big LED screen.
7. With its own micro printer, print and save test data at any time.
Application:
cable Variable frequency resonant system
Generator frequency withstand voltage test equipment;
Substation electrical equipment ac withstand voltage test system
I. Product Usage :
This test set model CHX-810KVA/54KV, 135KV is designed for 35KV and 110KV class XLPE cable on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 54KV or 135KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test for XLPE cables 35KV within 5km and 132KV class within 1km .
Test range of the set is as following:
1. 5km of 35kV/300mm2 cable, tested capacitance ≤0.97uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.
2, 1km of 132kV/630mm2 cable , tested capacitance ≤ 0.201uF, test frequency 30-300Hz, test voltage 128kV, test time 60min.
II. General Technical Data
III. Main Components:
SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension |
1 | Variable frequency power | FKVF-30kW/380V | 1piece | 35kgs | 480*480*520mm |
2 | Excitation transformer | CQSB(J)-30kVA/2.5KV,5KV | 1piece | 130kgs | 550*550*580mm |
3 | HV resonant test reactor | CHX(kf)-81kVA/27kV/34H | 10pieces | 75kgs | D480*H520mm |
4 | Capacitive divider | TRF-150kV/2000pF | 1set | 30kgs | D200*H1250mm |
5 | Special test accessories | 1set |
IV. Test priciple :
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
VI.Accessories
VII. Other Optional Model
1. For GIS on-site test
Model | Rated voltage | Rated output current | Rated output capacity |
Application (From 45Hz starting) |
CHX-135KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-270KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS |
CHX-216KVA/216KV | 27KV*8 | 1A | 216KVA | For 123KV and below GIS |
CHX-270KVA/270KV | 27KV*10 | 1A | 270KVA | For 145KV and below GIS |
CHX-275KVA/275KV | 275KV | 2A | 275KVA | For 170KV and below GIS |
Special requirement can be made by order |
2. For 45KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-108/54 | 54KV | 2A | 108KVA | 45kV cable≤1km |
CHX-216/54 | 54KV | 4A | 216KVA | 45kV cable≤2km |
CHX-324/54 | 54KV | 6A | 324KVA | 45kV cable≤3km |
CHX-432/54 | 54KV | 8A | 432KVA | 45kV cable≤4km |
CHX-540/54 | 54KV | 10A | 540KVA | 45kV cable≤5km |
CHX-1080/54 | 54KV | 20A | 1080KVA | 45kV cable≤10km |
Special requirement can be made by order |
3. For 66KV XLPE cable on-site test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-160/80 | 80KV | 2A | 160KVA | 66kV cable≤0.5km |
CHX-320/80 | 80KV | 4A | 320KVA | 66kV cable≤1km |
CHX-640/80 | 80KV | 8A | 640KVA | 66kV cable≤2km |
CHX-960/80 | 80KV | 12A | 960KVA | 66kV cable≤3km |
CHX-1280/80 | 80KV | 16A | 1280KVA | 66kV cable≤4km |
CHX-1600/80 | 80KV | 20A | 1600KVA | 66kV cable≤5km |
CHX-3200/80 | 80KV | 40A | 3200KVA | 66kV cable≤10km |
CHX-9600/80 | 80KV | 120A | 9600KVA | 66kV cable≤20km |
Special requirement can be made by order |
Contact Person: Sales Manager
Tel: +8613707144739